1. Managing Removable Media (Overview) 2. Managing Removable Media (Tasks) 3. Accessing Removable Media (Tasks) 4. Writing CDs and DVDs (Tasks) 5. Managing Devices (Overview/Tasks) 6. Dynamically Configuring Devices (Tasks) 7. Using USB Devices (Overview) 9. Using InfiniBand Devices (Overview/Tasks) 11. Administering Disks (Tasks) 12. SPARC: Adding a Disk (Tasks) 13. x86: Adding a Disk (Tasks) 14. Configuring Solaris iSCSI Targets and Initiators (Tasks) The iSCSI Technology (Overview) Setting Up Solaris iSCSI Targets and Initiators (Task Map) How to Prepare for a Solaris iSCSI Configuration How to Configure iSCSI Target Discovery How to Remove Discovered iSCSI Targets Monitoring Your iSCSI Configuration How to Enable Multiple iSCSI Sessions for a Target 15. Configuring and Managing the Solaris Internet Storage Name Service (iSNS) 16. The format Utility (Reference) 17. Managing File Systems (Overview) 18. Creating UFS, TMPFS, and LOFS File Systems (Tasks) 19. Mounting and Unmounting File Systems (Tasks) 20. Using The CacheFS File System (Tasks) 21. Configuring Additional Swap Space (Tasks) 22. Checking UFS File System Consistency (Tasks) 23. UFS File System (Reference) 24. Backing Up and Restoring File Systems (Overview) 25. Backing Up Files and File Systems (Tasks) 26. Using UFS Snapshots (Tasks) 27. Restoring Files and File Systems (Tasks) 28. UFS Backup and Restore Commands (Reference) 29. Copying UFS Files and File Systems (Tasks) |
Troubleshooting iSCSI Configuration ProblemsThe following tools are available to troubleshoot general iSCSI configuration problems:
Both tools can filter iSCSI packets on port 3260. The following sections describe various iSCSI troubleshooting and error message resolution scenarios. No Connections to the iSCSI Target From the Local SystemHow to Troubleshoot iSCSI Connection Problems
iSCSI Device or Disk Is Not Available on the Local SystemHow to Troubleshoot iSCSI Device or Disk Unavailability
Use LUN Masking When Using the iSNS Discovery MethodAvoid using iSNS discovery domain as the means to control storage authorization to specific initiators. Use LUN masking instead if you want to make sure that only authorized initiators can access a LUN. If you remove a target from a discovery domain while the target is in use, the iSCSI initiator does not log out from this target. If you do not want this initiator to access this target (and the associated LUNs), you will have to use LUN masking. Simply removing the target from the discovery domain is not sufficient. General iSCSI Error MessagesThis section describes the iSCSI messages that might be found in the /var/adm/messages file and potential solutions for recovery. The message format is as follows: iscsi TYPE (OID) STRING (STATUS-CLASS#/STATUS-DETAIL#)
iscsi connection(OID) login failed - Miscellaneous iSCSI initiator errors. Cause:The device login failed due to some form of initiator error. iscsi connection(OID) login failed - Initiator could not be successfully authenticated. Cause:The device could not successfully authenticate the initiator. Solution:If applicable, verify that the settings for CHAP names, CHAP passwords or RADIUS are correct. iscsi connection(OID) login failed - Initiator is not allowed access to the given target. Cause:The device will not allow the initiator access to the iSCSI target device. Solution:Verify your initiator name and confirm that it is properly masked or provisioned by the storage device. iscsi connection(OID) login failed - Requested ITN does not exist at this address. Cause:The device does not provide access to the iSCSI target name (ITN) that you are requesting. Solution:Verify the initiator discovery information is entered properly and that the storage device is configured properly. iscsi connection(OID) login failed - Requested ITN has been removed and no forwarding address is provided. Cause:The device can no longer provide access to the iSCSI target name (ITN) that you are requesting. Solution:Verify that the initiator discovery information has been specified properly and the storage device has been configured properly. iscsi connection(OID) login failed - Requested iSCSI version range is not supported by the target. Cause:The initiator's iSCSI version is not supported by the storage device. iscsi connection(OID) login failed - No more connections can be accepted on this Session ID (SSID). Cause:The storage device cannot accept another connection for this initiator node to the iSCSI target device. iscsi connection(OID) login failed - Missing parameters (e.g., iSCSI initiator and/or target name). Cause:The storage device is reporting that the initiator or target name has not been properly specified. Solution:Properly specify the iSCSI initiator or target name. iscsi connection(OID) login failed - Target hardware or software error. Cause:The storage device encountered a hardware or software error. Solution:Consult the storage documentation or contact the storage vendor for further assistance. iscsi connection(OID) login failed - iSCSI service or target is not currently operational. Cause:The storage device is currently not operational. Solution:Consult the storage documentation or contact the storage vendor for further assistance. iscsi connection(OID) login failed - Target has insufficient session, connection or other resources. Cause:The storage device has insufficient resources. Solution:Consult the storage documentation or contact the storage vendor for further assistance. iscsi connection(OID) login failed - unable to initialize authentication iscsi connection(OID) login failed - unable to set authentication iscsi connection(OID) login failed - unable to set username iscsi connection(OID) login failed - unable to set password iscsi connection(OID) login failed - unable to set ipsec iscsi connection(OID) login failed - unable to set remote authentication Cause:The initiator was unable to initialize or set authentication properly. Solution:Verify that your initiator settings for authentication are properly configured. iscsi connection(OID) login failed - unable to make login pdu Cause:The initiator was unable to make a login payload data unit (PDU) based on the initiator or storage device settings. Solution:Try resetting any target login parameters or other nondefault settings. iscsi connection(OID) login failed - failed to transfer login iscsi connection(OID) login failed - failed to receive login response Cause:The initiator failed to transfer or receive a login payload data unit (PDU) across the network connection. Solution:Verify that the network connection is reachable. iscsi connection(OID) login failed - received invalid login response (OP CODE) Cause:The storage device has responded to a login with an unexpected response. iscsi connection(OID) login failed - login failed to authenticate with target Cause:The initiator was unable to authenticate the storage device. Solution:Verify that your initiator settings for authentication are properly configured. iscsi connection(OID) login failed - initiator name is required Cause:An initiator name must be configured to perform all actions. Solution:Verify that the initiator name is configured. iscsi connection(OID) login failed - authentication receive failed iscsi connection(OID) login failed - authentication transmit failed Cause:The initiator was unable to transmit or receive authentication information. Solution:Verify the network connectivity with storage device or the RADIUS server as applicable. iscsi connection(OID) login failed - login redirection invalid Cause:The storage device attempted to redirect the initiator to an invalid destination. Solution:Consult the storage documentation or contact the storage vendor for further assistance. iscsi connection(OID) login failed - target protocol group tag mismatch, expected <TPGT>, received <TPGT> Cause:The initiator and target had a TPGT (target portal group tag) mismatch. Solution:Verify your TPGT discovery settings on the initiator or the storage device. iscsi connection(OID) login failed - can't accept PARAMETER in security stage Cause:The device responded with an unsupported login parameter during the security phase of login. Solution:The parameter name is noted for reference. Consult the storage documentation or contact the storage vendor for further assistance. iscsi connection(OID) login failed - HeaderDigest=CRC32 is required, can't accept VALUE iscsi connection(OID) login failed - DataDigest=CRC32 is required, can't accept VALUE Cause:The initiator is only configured to accept HeaderDigest or DataDigest that is set to CRC32 for this target. The device returned the value of VALUE. Solution:Verify that the initiator and device digest settings are compatible. iscsi connection(OID) login failed - HeaderDigest=None is required, can't accept VALUE iscsi connection(OID) login failed - DataDigest=None is required, can't accept VALUE Cause:The initiator is only configured to accept HeaderDigest or DataDigest that is set to none for this target. The device returned the value of VALUE. Solution:Verify that the initiator and device digest settings are compatible. iscsi connection(OID) login failed - can't accept PARAMETER Cause:The initiator does not support this parameter. iscsi connection(OID) login failed - can't accept MaxOutstandingR2T VALUE Cause:The initiator does not accept MaxOutstandingR2T of the noted VALUE. iscsi connection(OID) login failed - can't accept MaxConnections VALUE Cause:The initiator does not accept the maximum connections of the noted VALUE. iscsi connection(OID) login failed - can't accept ErrorRecoveryLevel VALUE Cause:The initiator does not accept an error recovery level of the noted VALUE. iscsi session(OID) NAME offline Cause:All connections for this target NAME have been removed or failed. iscsi connection(OID) failure - unable to schedule enumeration Cause:The initiator was unable to enumerate the LUNs on this target. Solution:You can force LUN enumeration by running the devfsadm -i iscsi command. For more information, see devfsadm(1M). iscsi connection(OID) unable to connect to target NAME (errno:ERRNO) Cause:The initiator failed to establish a network connection. Solution:For information about the specific ERRNO on the connection failure, see the /usr/include/sys/errno.h file. |
||
|